Description
Overview
Essential details:PVG32-1 DANFOSS PVG 32 group with open center PVP (PVB with flow control spool)
When the pump starts, and the main spools in the individual basic modules (11) are in the neutral position, oil flows from the pump, through connection P, across the pressure adjustment spool (6) to tank. The oil flow led across the pressure adjustment spool determines the pump pressure (stand-by pressure).
When one or more of the main spools actuate, the highest load pressure is fed through the shuttle valve circuit (10) to the spring chamber behind the pressure adjustment spool (6), and completely or partially closes the connection to tank.
Pump applies pressure to the right-hand side of the pressure adjustment spool (6). The pressure relief valve (1) opens if the load pressure exceeds the set value, diverting pump flow back to tank. In a pressure-compensated basic module the compensator (14) maintains a constant Pressure drop across the main spool—both when the load changes and when a module with a higher load pressure is actuated.
With a non pressure-compensated basic module incorporating a load drop check valve (18) in channel P, the check valve prevents return oil flow. The basic module can have the load drop check valve in channel P for functions with over-center valves.
The shock valves PVLP (13) with fixed setting and the suction valves PVLA (17) on ports A and B are used for the protection of the individual working function against overload and/or cavitation.
An adjustable Load Sensing (LS) pressure limiting valve (12) can be built into the A and B ports of pressure-compensated basic modules to limit the pressure from the individual working functions.
The LS pressure limiting valves save energy compared to the shock valves PVLP. With PVLP all the oil flow to the working function flows across the combined shock and suction valves to tank if the pressure exceeds the fixed setting. With LS pressure limiting valves, an oil flow of about 2 l/min [0.5 US gal/min] flows across the LS pressure limiting valve to tank if the pressure exceeds the valve setting.
In the closed center version, an orifice (5) and a plug (7) are fitted instead of the plug (4). This means that the pressure adjustment spool (6) only opens to tank when the pressure in channel P exceeds the set value of the pressure relief valve (1).
In LS systems, the load pressure flows to the pump regulator via the LS connection (8). In the neutral position the pump control sets the displacement so that leakage in the system is compensated to maintain the set stand-by pressure. When a main spool is actuated, the pump regulator adjusts the displacement to maintain the set differential pressure between P and LS.
The pressure relief valve (1) in PVP should be set at a pressure of approximately 30 bar [435 psi] above maximum system pressure (set on the pump or external pressure relief valve).
Why Choose Us PVG32-1 DANFOSS PVG 32 group with open center PVP (PVB with flow control spool)
We are a professional service provider in the field of industrial automation components. We mainly provide PLC module, DCS card, ESD system card, vibration monitoring system card, turbine control system module, gas generator components, we have established a close cooperative relationship with many PLC and DCS product maintenance service providers. The company has established an e-commerce operation model, which reduces the intermediate links for consumers and provides consumers with high-quality products and satisfactory services. The company has a complete logistics supply system. We can buy directly from abroad and supply equipment and spare parts from different countries and manufacturers to solve your problem.
Sales Manager | SUNNY |
sales@xiongbagk.cn | |
(+86)-18059884797 | |
Skype | SUNNY |
Mobile | (+86)-18059884797 |
questions and answers
Q: Do you provide warranty for the goods?
A: Yes, we provide warranty for all the goods from us.
Q: Could you provide technology support?
A: We’re in this field more than 15 years. If there’s any problem, please contact with us,we’ll provide suggestion from our engineer to help you solve problem.
Q: Do you keeps goods in stock or only trading?
A: We have large warehouse for goods. Keep lots of goods in warehouse, so could promise fast delivery.
Q:Does your goods are new and original ?
A: yes ,they are new and original
Superiority products PVG32-1 DANFOSS PVG 32 group with open center PVP (PVB with flow control spool)
ABB | BENTLY | GE | Yokogawa |
CI522A 3BSE018283R1 | 3500/60 163179-01 | UR8FH | Yokogawa PW481-10 |
CI546 3BSE012545R1 | 3500/32 125712-01 | 269PLUS-100P-HI | Yokogawa PW482-50 |
SB510 3BSE000860R1 | 3500/40M 140734-01 | UR8HH | Yokogawa SAI143-H33/PRP |
TC520 3BSE001449R1 | 3500/15 127610-01 | SR469-P5-HI-A20-E | Yokogawa SAI143-S03 |
SR511 3BSE000863R1 | 3500/22M 138607-01 | CB06551 PRD-B040SSIB-63 | Yokogawa SAI533-H33 |
SC520 3BSE003816R1 | 3500/20 125744-02 | CB06551 | Yokogawa SAI533-H33/PRP |
SC510 3BSE003832R1 | 3500/92 136180-01 | VMIVME-7455 | Yokogawa SB401-10 |
RE522 3BSE000743R1 | 1900/65A-01-01-01-00-00 | VMIVME-4140 | Yokogawa SB401-50 |
DSRF197 3BSE019297R1 | 3500/92 136180-01 | VMIVME-2128 | Yokogawa SCP451-53 |
DSAO120A 3BSE018293R1 | 3400/42M | IC695CHS016 | Yokogawa SDV144-S33 |
DSDP170 57160001-ADF | 3500/15 106M1079-01 | E33NCHA-LNN-NS-00 | Yokogawa SDV531-L33 |
TC512V1 3BSE018059R1 | 3500/15-07-00-00 | IC200PWR001D | Yokogawa SDV531-L33/STB4D-00 |
DSDO115A 3BSE018298R1 | 125720-01 | IC698CMX016 | Yokogawa SDV541-S33 |
DSAI130D 3BSE003127R1 | 3500/15 127610-01 | VMIVME-5567-000 | Yokogawa SEC401-51 |
DSDI110AV1 3BSE018295R1 | 128229-01 | VME-7750 | Yokogawa SEC401-11 |
PM904F 3BDH001002R0001 | 3500/53 133388-01 | VME-7750-746001 | Yokogawa SNT401-13 |
TP854 3BSE025349R1 | 3500/42M 176449-02 | IS215UCVEM09A | Yokogawa SNT501-13 |
PM865K01 3BSE031151R1 | 3500/22M-01-01-01 | VMIVME-7698 | Yokogawa SSB401-13 |
TB850 3BSC950193R1 | 3500/22M | IC695CRU320 | Yokogawa STB4D-00 |
SM811K01 32SE018173R1 | 1900/65A | CB06560 PRD-B040SAIB-62 | Yokogawa STB4S-00 |