Sale!

REC670  Bay control REC670 1MRK511313-BEN

The auto-reclose for single-, two-, and/or three-phase reclose includes priority circuits for multi-breaker arrangements. It cooperates with the synchrocheck function with high-speed or delayed reclosing. Several breaker failure functions are available to provide a breaker failure function independent from the protection IEDs, also for a complete one- and a half breaker diameter.
Disturbance recording and fault locator are available to allow independent post-fault analysis after primary disturbances in case of a failure in the protection system.

Categories: ,

Description

Overview


Essential details:REC670  Bay control REC670 1MRK511313-BEN

The auto-reclose for single-, two-, and/or three-phase reclose includes priority circuits for multi-breaker arrangements. It cooperates with the synchrocheck function with high-speed or delayed reclosing. Several breaker failure functions are available to provide a breaker failure function independent from the protection IEDs, also for a complete one- and a half breaker diameter.
Disturbance recording and fault locator are available to allow independent post-fault analysis after primary disturbances in case of a failure in the protection system.
Duplex communication channels for transfer of up to 192 intertrip and binary signals are available on each remote-end data communication card (LDCM). Typical applications are the communication between 670–series IEDs inside the station or with 670–series in a remote station as remote I/O.
REC670 can be used in applications with the IEC 61850-9-2LE process bus with up to six Merging Units (MU).
Logic is prepared with a graphical tool. The advanced logic capability allows special applications such as automatic opening of disconnectors in multi-breaker arrangements, closing of breaker rings, load transfer logics and so on. The graphical configuration tool ensures simple and fast testing and commissioning.

Four packages have been defined for following applications:
• Single breaker (double or single bus) arrangement (A30)
• Bus coupler for double busbar (A31)
• Double breaker arrangement (B30)
• 1 ½ breaker arrangement for a complete diameter (C30)
Optional functions are available in PCM600 Application Configuration Tool and can be configured by the user. Interface to analog and binary IO:s are configurable without need of configuration changes. Analog and control circuits have been pre-defined. Other signals need to be applied as required for each application. The main differences between the packages above are the interlocking modules and the number of apparatuses to control.

REC670

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@xiongbagk.cn

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

REC670  Bay control REC670 1MRK511313-BEN

Synchrocheck, energizing check, and synchronizing SESRSYN The Synchronizing function allows closing of asynchronous networks at the correct moment including the breaker closing time, which improves the network stability.
Synchrocheck, energizing check, and synchronizing SESRSYN function checks that the voltages on both sides of the circuit breaker are in synchronism, or with at least one side dead to ensure that closing can be done safely.
SESRSYN function includes a built-in voltage selection scheme for double bus and 1½ breaker or ring busbar arrangements.
Manual closing as well as automatic reclosing can be checked by the function and can have different settings.
For systems, which are running asynchronous, a synchronizing function is provided. The main purpose of the synchronizing function is to provide controlled closing of circuit breakers when two asynchronous systems are going to be connected. The synchronizing function evaluates voltage difference, phase angle difference, slip frequency and frequency rate of change before issuing a controlled closing of the circuit breaker. Breaker closing time is a parameter setting