Sale!

SCXI-1100 Voltage Input Module for SCXI NI

SCXI-1100 Voltage Input Module for SCXI NI

Manufacturers :NI
Model(s)  :SCXI-1100
Additional Information :Voltage Input Module for SCXI
Estimated Shipping Size
Dimensions: 163 × 38 × 58mm
Weight:.0.35 kg
Country of Origin: United States of America

 

Categories: ,

Description

Overview


Essential details:SCXI-1100 Voltage Input Module for SCXI NI

Products Description

The National Instruments SCXI-1100 (Part Number: 776572-00, 181690-01) is a 32 differential Channel Voltage Input Module for SCXI. This module is created for affordable signal conditioning of millivolt, volt, and current signals. All channels are multiplexed with the option of several gain ranges with a jumper-selectable 4 Hz low pass filter. The channels are multiplexed into one channel of a controlling DAQ instrument. The outcome is a higher number of channels for the DAQ system. An additional shielded terminal block has screw terminals for simple signal attachment to the SCXI 1100 module. Additionally, a temperature sensor for cold-junction compensation of thermocouples is included on the terminal block. The cold-junction reference can be multiplexed with the 32 channels on the NI SCXI-1100. The other option is for the cold-junction reference to be jumper connected to a different channel of the data acquisition board. The NI device is equipped with a 96-pin male DIN C front connector and a 50-pin male ribbon cable rear connector. The DC coupled device has a maximum working voltage of ±10 V.

Packing & Shipping

Package Type: New and original factory separately sealed inner box

Delivery time: Prepare delivery inventory;

The goods will be packed according to the international standard.

1. We will deliver the goods within 3 working days after payment.

2. The new and original factory seal the inner box separately

3. We can send it to you by DHL/TNT/UPS/EMS/ fedex.

Please contact us directly and we will deliver the goods according to your requirements. Best quality assurance

4. We promise that all goods we supply are 100% new and original

5. One year warranty (after delivery date).

Payment method: We accept telegraphic transfer

SCXI-1100

The NI SCXI-1100 module can be utilized with the NI MIO boards, including the PC-LPM-16, Lab-LC, Lab-PC+, Lab-PC, and Lab-NB. However, these boards can solely accomplish one-channel reads; they cannot scan the module.

The SCXI-1100 Voltage Input Module can be used with a variety of terminal blocks, including rack-mounted, thermocouple plugs, screw terminals, BNC connectors, DIN-rail mount, solder pins, and front-mounting terminal blocks. The SCXI 1100 can be used with the following National Instruments Terminal Blocks: the SCXI-1300, SCXI-1303, SCXI-1308, BNC-2095, TC-2095, TBX-1303, TBX-96, and SCXI-1310. A few of these terminal blocks have extra features. For example, a special feature of the SCXI-1310 is the affordable connector and shell assembly. Also, the BNC-2095 has prewired ground referencing. The TC-2095 has isothermal construction and switchable ground referencing. In addition, the SCXI-1303 has pluggable ground referencing. The NI device measures 1.2 x 6.8 x 8.0 in. in physical dimensions. It has a recommended operating temperature range of 0° to 50° C.

Why Choose Us SCXI-1100 Voltage Input Module for SCXI NI

We are a professional service provider in the field of industrial automation components. We mainly provide PLC module, DCS card, ESD system card, vibration monitoring system card, turbine control system module, gas generator components, we have established a close cooperative relationship with many PLC and DCS product maintenance service providers. The company has established an e-commerce operation model, which reduces the intermediate links for consumers and provides consumers with high-quality products and satisfactory services. The company has a complete logistics supply system. We can buy directly from abroad and supply equipment and spare parts from different countries and manufacturers to solve your problem.

Superiority products SCXI-1100 Voltage Input Module for SCXI NI

NI GE Yokogawa Woodward
pxie-8861 UR8FH Yokogawa PW481-10 Woodward  8440-2050
pxie-8135 269PLUS-100P-HI Yokogawa PW482-50 Woodward  8440-2116
pxie-8301 UR8HH Yokogawa SAI143-H33/PRP Woodward 8440-2252
pxie-8880 SR469-P5-HI-A20-E Yokogawa SAI143-S03 Woodward  8440-2251
pxie-8840 CB06551 PRD-B040SSIB-63 Yokogawa SAI533-H33 Woodward  8440-2254
pxie-8881 CB06551 Yokogawa SAI533-H33/PRP Woodward  8440-2255
pxie-8381 VMIVME-7455 Yokogawa SB401-10 Woodward  8440-2150
pxie-8360 VMIVME-4140 Yokogawa SB401-50 Woodward   8440-2078
pxie-8821 VMIVME-2128 Yokogawa SCP451-53 Woodward  8440-1809
pxie-8510 IC695CHS016 Yokogawa SDV144-S33 Woodward  8440-2107
pxie-8398 E33NCHA-LNN-NS-00 Yokogawa SDV531-L33 Woodward  8440-1894
pxie-8384 IC200PWR001D Yokogawa SDV531-L33/STB4D-00 Woodward  8440-2078
pxie-8370 IC698CMX016 Yokogawa SDV541-S33 Woodward  8440-2077
pxie-8361 VMIVME-5567-000 Yokogawa SEC401-51 Woodward  8440-1801
pxie-8394 VME-7750 Yokogawa SEC401-11 Woodward  8440-2085
pxie-8374 VME-7750-746001 Yokogawa SNT401-13 Woodward  8440-2153