Description
Overview
Essential details:SCXI-1104C Voltage Input Module for SCXI NI
Products Description
The National Instruments SCXI-1104C (Part Number: 776572-04C, 183087H-05) Voltage Input Module has 32 differential channels and is created for the signal conditioning of higher voltage signals. This model comes with a 10 kHz cut-off frequency filter. If the user wants to utilize the NI SCXI-1104C in a ribbon-cabled multichassis SCXI system, then they need to use the SCXI-1346 multichasis adapter with it. If the user chooses not to auto-detect the SCXI modules, then they must add the modules individually. This can be accomplished by following the instructions in the user manual.
Packing & Shipping
Package Type: New and original factory separately sealed inner box
Delivery time: Prepare delivery inventory;
The goods will be packed according to the international standard.
1. We will deliver the goods within 3 working days after payment.
2. The new and original factory seal the inner box separately
3. We can send it to you by DHL/TNT/UPS/EMS/ fedex.
Please contact us directly and we will deliver the goods according to your requirements. Best quality assurance
4. We promise that all goods we supply are 100% new and original
5. One year warranty (after delivery date).
Payment method: We accept telegraphic transfer
While utilizing software, the user can arrange pin 1,2, 4, or 19 to link to the analog ground of the Voltage Input Module. The user can utilize the pin that is linked to the analog ground as an analog power ground tie point to the SCXI-1104C. An important fact to remember is that the NI SCXI-1104C analog output is not overvoltage-protected. Therefore, applying external voltages to this output can damage the module. The analog outputs are short-circuit protected though. The device has a recommended warm-up time of 20 minutes and an operating temperature of 0 to 50 °C.
The National Instruments SCXI-1104C module can be calibrated by applying precision voltages to the channel inputs and/or grounding the channel inputs. This module should be recalibrated a minimum of once per year or anytime it is operated outside of the specified temperature range. The NI SCXI-1104C Voltage Input Module can be calibrated with a multiranging 8.5 digital multimeter. The device has a cut-off frequency of 10 kHz. When users complete a measurement with NI Software, the driver automatically uses the calibration constants to adjust the measured voltages to the correct values.
The NI-DAQ version 6.5.1 (or higher) is the software driver used in running the SCXI-1104C. To install the driver, an Application Development Environment such as LabVIEW, BridgeVIEW, LabWindows/CVI, Visual Basic (ComponentWorks), C,C++, VirtualBench, or Measure is required. The device has a 50-pin male ribbon cable back connector and a 96-pin male DIN C front connector.
Why Choose Us SCXI-1104C Voltage Input Module for SCXI NI
We are a professional service provider in the field of industrial automation components. We mainly provide PLC module, DCS card, ESD system card, vibration monitoring system card, turbine control system module, gas generator components, we have established a close cooperative relationship with many PLC and DCS product maintenance service providers. The company has established an e-commerce operation model, which reduces the intermediate links for consumers and provides consumers with high-quality products and satisfactory services. The company has a complete logistics supply system. We can buy directly from abroad and supply equipment and spare parts from different countries and manufacturers to solve your problem.
Superiority products SCXI-1104C Voltage Input Module for SCXI NI
NI | GE | Yokogawa | Woodward |
pxie-8861 | UR8FH | Yokogawa PW481-10 | Woodward 8440-2050 |
pxie-8135 | 269PLUS-100P-HI | Yokogawa PW482-50 | Woodward 8440-2116 |
pxie-8301 | UR8HH | Yokogawa SAI143-H33/PRP | Woodward 8440-2252 |
pxie-8880 | SR469-P5-HI-A20-E | Yokogawa SAI143-S03 | Woodward 8440-2251 |
pxie-8840 | CB06551 PRD-B040SSIB-63 | Yokogawa SAI533-H33 | Woodward 8440-2254 |
pxie-8881 | CB06551 | Yokogawa SAI533-H33/PRP | Woodward 8440-2255 |
pxie-8381 | VMIVME-7455 | Yokogawa SB401-10 | Woodward 8440-2150 |
pxie-8360 | VMIVME-4140 | Yokogawa SB401-50 | Woodward 8440-2078 |
pxie-8821 | VMIVME-2128 | Yokogawa SCP451-53 | Woodward 8440-1809 |
pxie-8510 | IC695CHS016 | Yokogawa SDV144-S33 | Woodward 8440-2107 |
pxie-8398 | E33NCHA-LNN-NS-00 | Yokogawa SDV531-L33 | Woodward 8440-1894 |
pxie-8384 | IC200PWR001D | Yokogawa SDV531-L33/STB4D-00 | Woodward 8440-2078 |
pxie-8370 | IC698CMX016 | Yokogawa SDV541-S33 | Woodward 8440-2077 |
pxie-8361 | VMIVME-5567-000 | Yokogawa SEC401-51 | Woodward 8440-1801 |
pxie-8394 | VME-7750 | Yokogawa SEC401-11 | Woodward 8440-2085 |
pxie-8374 | VME-7750-746001 | Yokogawa SNT401-13 | Woodward 8440-2153 |