Essential details:SPM-D11 8440-1706 SPM-D11 category of synchronizers
This unit is a part of their SPM-D11 category of synchronizers, and designated under the numerical ID of 8440-1706. The 8440-1706 model is outfitted with the capability to provide units with a combined synchronizing ability for a circuit breaker, power factor and load factor control, and the option for isochronous load sharing and generator protection. The 8440-1706 unit is also built with a choice for operators to implement while the generator voltage matching is occuring; either the phase matching can also occur, or the slip frequency synchronization can be enabled. The mains parallel operating features the 8440-1706 is included with is a wide range of features. There is the real power control, the true RMS power calculation, as well as the soft unload feature, and the power factor control and setpoint by the adjusted parameters. This unit is also outfitted with isolated operation control features and dead bus operation features. The 8440-1706 is designed with the standard dimensions, measuring at 144 millimeters by 72 millimeters by 122 millimeters. It weighs at least 800 grams, or 1.76 lbs. The integrated LCD display has a two-line display, and provides users with information for system diagnostics and alarms.
lf you need to inquire or purchase ,please send the product models to my email or call medirectly .
sunny He
[Email] sales@xiongbagk.cn
[Mobile] 86-18059884797
[WhatsApp] 86-18059884797
[Skype] sales@saulcontrol.com
SPM-D11 8440-1706 SPM-D11 category of synchronizers
The SPM–D11 is a microprocessor-based synchronizer designed for use on one or three-phase AC generators equipped with Woodward or other compatible speed controls and automatic voltage regulators. The SPM–D11 synchronizer provides automatic frequency, phase and voltage matching using either analog- or discrete output bias signals.
It combines synchronizing for one circuit breaker, load and power factor control or isochronous load sharing and generator protection.
DESCRIPTION
Synchronizing
• Phase match or slip frequency synchronization with voltage matching
• Two-phase sensing of generator and bus
• Selectable operating modes like SPM-A (Run, Check, Permissive, and OFF)
• Synchro-check possible
• Synchronization time monitoring
• Load/var sharing Mains parallel operation
• Real power control
• True RMS power calculation
• Generator real power setpoint by parameter (2 values) or via 0/4 to 20 mA
• Soft unloading
• Power factor control
• Power factor setpoint by parameter
• Power limit value with relay output Isolated operation
• Frequency control
• Voltage control Dead bus operation
• Closing of breaker on demand
It combines synchronizing for one circuit breaker, load and power factor control or isochronous load sharing and generator protection.
DESCRIPTION
Synchronizing
• Phase match or slip frequency synchronization with voltage matching
• Two-phase sensing of generator and bus
• Selectable operating modes like SPM-A (Run, Check, Permissive, and OFF)
• Synchro-check possible
• Synchronization time monitoring
• Load/var sharing Mains parallel operation
• Real power control
• True RMS power calculation
• Generator real power setpoint by parameter (2 values) or via 0/4 to 20 mA
• Soft unloading
• Power factor control
• Power factor setpoint by parameter
• Power limit value with relay output Isolated operation
• Frequency control
• Voltage control Dead bus operation
• Closing of breaker on demand