Sale!

SYN5302 SYNCHROTACT 5 synchronous device

IS420UCSBH1A REV.H highly reliable and versatile module

SYN5302 SYNCHROTACT 5 Synchronous device is a synchronous device used in power systems, mainly for the simultaneous operation of generator sets. The main function of the synchronous device is to ensure that the voltage, frequency and phase of the generator set are consistent with or close to the corresponding parameters of the grid when the generator set is connected to the grid, so as to achieve a smooth and safe grid-connected operation.

Categories: ,

Description

Overview


Essential details:IS420UCSBH1A REV.H highly reliable and versatile module

SYN5302 SYNCHROTACT 5 Synchronous device is a synchronous device used in power systems, mainly for the simultaneous operation of generator sets. The main function of the synchronous device is to ensure that the voltage, frequency and phase of the generator set are consistent with or close to the corresponding parameters of the grid when the generator set is connected to the grid, so as to achieve a smooth and safe grid-connected operation.

SYN5302 SYNCHROTACT 5 synchronous device features are as follows:

High precision measurement: The synchronous device can measure the voltage, frequency and phase parameters of the generator set and the grid with high precision to ensure the accuracy and reliability of the grid-connected operation.

Multiple synchronization modes: SYN5302 SYNCHROTACT 5 Synchronization device supports a variety of synchronization modes, such as automatic synchronization, manual synchronization, rough synchronization and capture synchronization, to adapt to different grid-connected needs.

Automatic adjustment function: The device has an automatic adjustment function, which can automatically adjust the voltage and frequency of the generator set according to the measurement results, so that it matches the parameters of the power grid.

SYN5302 SYNCHROTACT 5 Synchronous device has perfect security protection functions, such as over voltage, under voltage, over frequency, under frequency and other protection, to ensure that in abnormal circumstances can be cut off in time, to protect the safety of equipment and system.

Intelligent operation: The synchronous device adopts advanced control technology and intelligent algorithm, which can realize automatic and intelligent operation and improve the efficiency and reliability of grid-connected operation.

In summary, the SYN5302 SYNCHROTACT 5 synchronous device is a powerful and stable synchronous device for all types of generator set grid-connection operations, ensuring a safe, stable and reliable grid-connection process.

SYN5201A-Z V217 3BHB006714R0217

lf you need to inquire or purchase ,please send the product models to my email or call medirectly .

sunny  He

[Email] sales@saulcontrol.com

[Mobile] 86-18059884797

[WhatsApp] 86-18059884797

[Skype] sales@saulcontrol.com

IS420UCSBH1A REV.H highly reliable and versatile module

Synchronous devices are widely used in power stations or industrial installations with self-contained power stations where generators need to be integrated into a separate grid or grid
The public grid synchronous device can also be used in the distribution system
The circuit breaker can only be closed if the two voltages are very close to the same time or the line operation will interrupt the generator load
Failure even in some extreme cases will cause damage to the generator body
Both as a manual grid-connected monitoring unit and as a standalone fully automatic synchronous device SYNCHROTACT 5 can be safely and reliably used
Perform these functions For a synchronous device we want it not only to close the circuit breaker at the exact time but also to be able to connect to the grid whenever necessary
Although it is common in concurrent systems to connect two independent functional channels of dual-channel output contactors in series to greatly increase reliability
Stop misconnection but this inevitably leads to a decrease in its availability by using a redundant dual-channel parallel output contact parallel synchronous system can be the same
Achieve high reliability and high availability
Generally, the two channels in the main synchronous system are composed of two fully automatic synchronous units while the bypass synchronous system is composed of two with synchronous detectors
The manual grid-connected device of the table is composed
In both systems the second channel usually includes a simultaneous check device